Schneider Electric TeSys LC1D25BD Contactor
Schneider Electric TeSys LC1D256BLS207 Contactor
| Brand: Schneider Electric SE | 
Schneider Electric SE
Schneider Electric SE is a European multinational company that specializes in digital automation and energy management. It addresses homes, buildings, data centres, infrastructure and industries, by combining energy technologies, real-time automation, software, and services.
Tags :
TeSys D contactor, 3 poles (3NO), for motor control in railway applications up to 25A/690V AC-3/3e (11kW@400V). It provides a low consumption 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, CCC, EAC) and compliant with the railway European standard EN 45545 R22HL3, Green Premium product (RoHS/REACh).
| Motor power kW | 5.5 kW at 220/230 V AC 50 Hz (AC-3) 11 kW at 380/400 V AC 50 Hz (AC-3) 11 kW at 415 V AC 50 Hz (AC-3) 11 kW at 440 V AC 50 Hz (AC-3) 15 kW at 500 V AC 50 Hz (AC-3) 15 kW at 660/690 V AC 50 Hz (AC-3) 5.5 kW at 220/230 V AC 50 Hz (AC-3e) 11 kW at 380/400 V AC 50 Hz (AC-3e) 11 kW at 415 V AC 50 Hz (AC-3e) 11 kW at 440 V AC 50 Hz (AC-3e) 15 kW at 500 V AC 50 Hz (AC-3e) 15 kW at 660/690 V AC 50 Hz (AC-3e) | 
|---|---|
| Pole contact composition | 3 NO | 
| Contact compatibility | M5 | 
| Protective cover | With | 
| Auxiliary contacts type | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 | 
| Auxiliary contact composition | 1 NO + 1 NC | 
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 | 
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 | 
| Overvoltage category | III | 
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit 40 A (at 60 °C) for power circuit | 
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 | 
| Rated breaking capacity | 450 A at 440 V for power circuit conforming to IEC 60947 | 
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit | 
| Time constant | 37 ms | 
| Control circuit type | DC low consumption | 
| Coil technology | With integral suppression device | 
| Control circuit voltage limits | 0.1...0.25 Uc (-40…70 °C):drop-out DC 0.7...1.25 Uc (-40…70 °C):operational DC | 
| Average impedance | 2 mOhm - Ith 40 A 50 Hz for power circuit | 
| Power dissipation per pole | 3.2 W AC-1 1.25 W AC-3 1.25 W AC-3e | 
| Minimum switching current | 5 mA for signalling circuit | 
| Minimum switching voltage | 17 V for signalling circuit | 
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | 
| Operating time | 55...75 ms closing 16...32 ms opening | 
| Maximum operating rate | 3600 cyc/h 60 °C | 
| Inrush power in W | 4 W (at 20 °C) | 
| Hold-in power consumption in W | 4 W at 20 °C | 
| Insulation resistance | > 10 MOhm for signalling circuit | 
| Connections - terminals | Control circuit: lugs-ring terminals - external diameter: 8 mm Power circuit: lugs-ring terminals - external diameter: 12 mm | 
| Tightening torque | Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5 Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5 Power circuit: 2.5 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M4 Power circuit: 2.5 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M4 | 
| Mounting support | Plate Rail | 
| Electrical durability | 1.65 Mcycles 25 A AC-3 at Ue <= 440 V 1.4 Mcycles 40 A AC-1 at Ue <= 440 V 1.65 Mcycles 25 A AC-3e at Ue <= 440 V | 
| Mechanical durability | 30 Mcycles | 
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | 
| Operating altitude | 0...3000 m | 
| Compatibility code | LC1D | 
| Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 EN 45545: R22 HL3 EN 45545: R26 HL3 DIN 5510-2 | 
| Product certifications | IEC CCC EAC UA TR UKCA | 
| Climatic withstand | Conforming to IACS E10 conforming to IEC 60947-1 Annex Q category D | 
|---|---|
| Ambient air temperature for storage | -60…80 °C | 
| Fire resistance | 850 °C conforming to IEC 60695-2-1 | 
| Height | 85 mm | 
| Width | 45 mm | 
| Depth | 101 mm | 
| Net weight | 0.37 kg | 
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor closed (15 Gn for 11 ms) Shocks contactor open (8 Gn for 11 ms) |